  • Measurement bandwidth range: 5 MHz–12 MHz
  • Maximum peak current: 750 A
  • Locking mechanism ensures reliable contact between upper and lower magnetic cores, with measurement accuracy up to 1%
  • Jaw diameter: 20 mm
  • Dual-range design for measuring different current levels
  • Audible and visual overcurrent alarm to prompt switching to the appropriate range
  • Overcurrent protection to prevent damage from overheating
  • Product Advantages
  • Model Comparison
  • Configure Your Instrument
  • Related Downloads
  • Related Products
  • 1mA–400A / DC~200kHz Current Probe

    up to ±1.5% accuracy, captures dynamic transients and high-frequency harmonics in SMPS and motor drives.

    Smart Auto-Zero & Ergonomic Design

    Power-on Auto Zero, large 20mm jaw opening, standard BNC output, universally compatible with mainstream oscilloscopes, and effortless workflow.

  • ModelBandwidthPeak currentResolutionAccuracyJaw diameter
    OC701512MHz300A30A: 10mA
    150A: 100mA
    ±1%± 10mA
    ±1%± 100mA
    20mm
    OC70306MHz500A50A: 10mA
    300A: 100mA
    ±1%± 10mA
    ±1%± 100mA
    20mm
    OC70505MHz750A75A: 10mA
    500A: 100mA
    ±1%± 10mA
    ±1%± 100mA
    20mm