XSA1000P Series Spectrum Analyzer

+ Frequency range 9kHz - 7.5GHz
+ -163 dBm Displayed Average Noise Level (DANL)
+ Phase noise -106 dBc/Hz @1GHz and offset at 10 kHz
+ Total amplitude accuracy <0.7 dB
+ 1 Hz minimum resolution bandwidth (RBW)
+ EMI pre-compliance test kit, optional EMC test software
+ Waterfall plot graphic, modulation signal quality analysis, audio demodulation, ect. multiple general and extended test functions.
+ tandard Pass/Fail on-site test and alert function
+ Adopt all-digital intermediate frequency technology
+ Multiple interfaces: USB Host, USB Device, LAN, earphone interface, HDMI
+ 10.4-inch multi-touch screen
Send Inquiry
Support
Product Details


1. 1Hz minimum resolution bandwidth (RBW),
    effectively distinguishingthe nearby signal


2.
Quick capture function 

Car rernote keys,TPMS tire pressure modules and smll wireless modules usually use ASKFSK mnodulation.

XSA800 can complete the capture of ASK/FSK signals,and directly obtain its center frequency, powerand offset parameters.


3.
Excellent small signal measurement capability

-163 dBm DANL (Displayed Average Noise Level),can observe weaker small signals


4.
More accurate low-noise measurements

Phase Noise < -106 dBc/Hz @1GHz at 10 kHz offset


5.
Pass/Fail function

Quickly determine if the test results pass

6.Waterfall plot graphic

View the behavior of varying signal parametersover time,track the frequency and power behaviorover the time,

particularly intermittent signals.The user can use waterfall plot graphic to analyzethe stability of a signal over the time,

or to identifyintermittent interference signals in communicationssystems.

7.Provide EMC test function on PC (requires optional software)

Built-in more than 200 mainstream EMC test standards and regulations templates.The user selects the correspondingtemplate,

and the software automaticaly sets the spectrum analyzer and records the test data.

The data and regulationscan be compared on the same screen.Users can also customize regulations for comparative analysis.

8.Provides EMl pre-compliance test function

Equipped with EMl filter (6dB) and quasi-peak detector as standard, it is more accurate for EMl pre-testand diagnosis,

and complete testing and production report can be completed by using supporting software.

9.Provide multiple extended function modes
Standard modulation signal quality analysis, audio demodulation, field strength measurerment,

charnel measurementand frequency counter,ect. multiple general and extended test functions.

modulation signal quality analysis


audio demodulation


channel measurement


frequency counter

Weight: Approx. 5kg (main device)

Dimensions:375 mm (W) x 185 mm (H) x 120 mm (D)

Specifications

Frequency

Frequency Range

 XSA1015P

9 kHz to 1.500000000 GHz

XSA1036P

9 kHz to 3.600000000 GHz

XSA1075P

9 kHz to 7.500000000 GHz

Frequency Resolution

1 Hz

Frequency Span

Span Range

0 Hz, 100 Hz to max frequency of instrument

Span Uncertainty

± span / (sweep points-1)

SSB Phase Noise(20℃ to 30℃,fc=1 GHz)

Carrier Offset

10 kHz

< -106 dBc/Hz

100 kHz

< -104 dBc/Hz

1 MHz

< -115 dBc/Hz

Bandwidth

Resolution Bandwidth(-3 dB)

1 Hz to 1 MHz, in 1-3-5-10 sequence

RBW Accuracy

< 5% nominal

Resolution Filter Shape Factor (60 dB : 3 dB)

<5 nominal

Video Bandwidth (-3 dB)

10 Hz to 3 MHz, in 1-3-5-10 sequence

Resolution Bandwidth(-6 dB)(EMI)

200 Hz,9 kHz,120 kHz,1 MHz

Amplitude

measurement range

 

XSA1015P

DANL to +10 dBm,100 kHz to 10 MHz, Preamp Off

DANL to +20 dBm,10 MHz to 1.5 GHz, Preamp Off

XSA1036P

DANL to +10 dBm,100 kHz to 10 MHz, Preamp Off

DANL to +20 dBm,10 MHz to 3.6 GHz, Preamp Off

XSA1075P

DANL to +10 dBm,100 kHz to 10 MHz, Preamp Off

DANL to +20 dBm,10 MHz to 7.5 GHz, Preamp Off

Max Input Level 

DC Voltage

50 V

Continuous RF power

Attenuation = 40 dB, +20 dBm(100mV)

Max. damage level

+30 dBm(1 W)

Display Average Noise Level (DANL)

Preamp Off

9 kHz to 1 MHz

-95 dBm (Typical), <-88 dBm

1 MHz to 500 MHz

-140 dBm (Typical), <-130dBm

500 MHz to 3.6 GHz

-138 dBm (Typical),<-128 dBm

3.6 GHz to 6 GHz

-134 dBm (Typical),<-124 dBm

6 GHz to 7.5 GHz

-129 dBm (Typical),<-119 dBm

Preamp On

100 kHz to 1 MHz

-135 dBm (Typical), <-128 dBm

1 MHz to 500 MHz

-160 dBm (Typical),<-150 dBm

 

500 MHz to 3.6 GHz

-158 dBm (Typical),<-148 dBm

3.6 GHz to 6 GHz

-154 dBm (Typical),<-144 dBm

6 GHz to 7.5 GHz

-149 dBm (Typical),<-139 dBm

Frequency response(20℃ to 30℃,30% to 70% relative humidity, input attenuation=10 dB, reference frequency= 50 MHz)

Preamp Off
(fc≥9kHz)

<0.7 dB

Preamp On
(fc≥50 MHz)

<1.0 dB

Difference and Accuracy

Uncertainty

fc = 50 MHz, peak detector, preamplifier off, attenuation = 10 dB, input signal level = -10 dBm, 20℃ to 30℃

< 0.4 dB

Tracking Generator (optional)

Frequency Range

 XSA1015P

100 kHz to 1.5 GHz

XSA1036P

100 kHz to 3.6 GHz

XSA1075P

100 kHz to 7.5 GHz

Output power

level range

-40 dBm to 0 dBm

Output level resolution

1 dB

Output flatness

Relative to 50 MHz

± 3 dB

Tracking generator spurious

Harmonic spurious

-20 dBc (Tracking generator output power -10 dBm)

Non-harmonic spurious

-20 dBc (Tracking generator output power -10 dBm)

Tracking generator to input terminal isolation

-60 dB (Tracking generator output power 0 dBm)

Interface

USB Host, USB Device,LAN,HDMI

Display

10.4 inches (1024*768) TFT LCD

Appearance

Dimensions

375 mm (W) × 185 mm (H) × 120 mm (D)

Weight

Approx. 5.0 kg (without package)

Accessories

The accessories subject to final delivery.

  • Power Cord
  • CD Rom
  • Quick Guide
  • USB Cable
  • N-N Cable (optional)
  • N-SMA Cable (optional)
  • SMA-SMA Cable (optional)
  • SMA Adaptor (optional)
  • Near Field Probe (optional)
  • N-SMA Adaptor (optional)
Inquiry
* Your Name :
Company Name :
* E-mail :
* Phone:
* Country :
   Address :
Product Serial No. :
* Comment :
* Confirmation Code :
Refresh